ZA FID AIR C PLUS

ZA FID AIR C PLUS

0.00

The AirGen series ZA FID AIR C PLUS is able to remove the total hydrocarbons to less than 0.05 ppm. Very compact, the ZA FID AIR C PLUS is available with a low noise built-in pistons compressor, 100% oil-free.

The filtration of the hydrocarbons is performed using a catalytic oven filled with palladium. The reduction of hydrocarbons, including methane, and carbon monoxide decrease the background noise level and gives much better baseline stability, considerably increasing detector sensitivity and ensuring precise analytical results. High efficiency coalescing pre-filtration and post filtration of particulate size greater than 0.01 microns are used to prevent any kind of particles from entering the analytical device. The ZA FID AIR C PLUS has a very simple and efficient interface. It can also be managed by the HydroGen  series HG PRO and HG BASIC and is ideal to supply Hydrocarbon free Air to FID detectors.

Categories: Premium Laboratory Gas Generators, Zero air generators

Description

Models: ZA FID AIR C PLUS 1.5 3.0 6.0 15.0 30.0
Zero Air outlet
Flow rate (Max) (1) 1.5 l/min 3 l/min 6 l/min 15 l/min 30 l/min
Outlet pressure (min) 2 bar (29 psi)
Outlet pressure (Max) 7 bar (101.5 psi)
Total hydrocarbon content < 0.05ppm
Total CO Nox SO2 content < 0.1 ppm – Only with option 6930.72.016
Dew-point (2) < -30°C (- 22°F) 

< -50°C (-58°F) – Only with option 6930.72.015

< -20°C (-4°F)
Communication
RS485 Standard
RS232 Standard
General data
Supply voltage (Max) (3) 110-120Vac (±10%) @ 50Hz – 115-120Vac (±10%) @ 60 Hz 

or

220-240Vac (±10%) @ 50/60 Hz

Connection type IEC320-C14
Nominal power (Max) 1000W
Fuse rating (5x20mm) 10A (250Vac – T)
Dimensions (W x D x H) 43 x 75 x 68 cm
Net weight 90 kg
Connections
Outlet port 1/4″ female BSPP
Operating/storage conditions
Operating temperature 5-35°C (41-95°F)
Storage temperature 1-50°C (34-122°F)
Humidity (max, non condensing) 80% [5-35°C (41-95°F)]
Noise (4) < 52 dB(A)
IP rating IP20
(1) With supply voltage frequency of 60 Hz
(2) Atmospheric Dew Point (ADP) at 25°C ambient temperature
(3) Adding the suffix “.110” to the standard code configures the unit for 115VAC supply voltage
(4) Measured at front of unit at a distance of 1,5 m, in accordance with ISO11201 (tolerance ±3 dB).
Models: ZA FID AIR C PLUS 1,5 3,0 6,0 15,0 30,0
Zero Air outlet
Flow rate (Max) 1.5 l/min 3 l/min 6 l/min 15 l/min 30 l/min
Outlet pressure (min) 2 bar (29 psi)
Outlet pressure (Max) 9 bar (130 psi)
Total hydrocarbon content < 0.05ppm
Dewpoint *1 < -30°C (- 22°F)
Communication
RS485 Standard
RS232 Standard
General data
Supply voltage 115 Vac (±10%) 50/60 Hz 

or

230 Vac (±10%) 50/60 Hz

Connection type IEC320-C14
Nominal power (Max) 1000W
Fuse rating (5x20mm) 10A (250Vac – T)
Dimensions (W x D x H) 43 x 75 x 68 cm
Net weight 90 kg
Connections
Outlet port 1/4″ female BSPP
Operating/storage conditions
Operating temperature 5-35°C (41-95°F)
Storage temperature 1-50°C (34-122°F)
Humidity (max, non condensing) 80% [5-35°C (41-95°F)]
Noise <52 dB(A)
IP rating IP20

Related Products

  • NG RACK 4U C
  • NG RACK 5U
  • NG RACK 7U
  • NG SIRIO